13914960448
18068076259
CN
/EN
富山阀门(江苏)有限公司
富山阀门(苏州)有限公司

Correlation Analysis of Flow Rate of Steam Pressure Reducing Valve

publish:2023-03-24 10:19:41   views :166
publish:2023-03-24 10:19:41  
166

In the use of steam systems, steam pressure reducing valves are a very common type of valve. Generally, using a single pressure reducing valve can achieve the pressure reducing effect, but in some special conditions, a single pressure reducing valve cannot meet the requirements for on-site use, and it is necessary to use parallel or series connection for pressure reduction. Next, we also want to make a specific analysis for everyone.

If the flow ratio of the steam pressure reducing valve system is greater than 10:1

When there is a large difference between the size and flow rate

We generally select two pressure reducing valves in parallel, and set the pressure gradient of the pressure reducing valve to ensure that the order of the pressure reducing valve is open. When the flow rate is low, only one pressure reducing valve will open first. When the downstream steam consumption increases significantly, the downstream pressure will decrease, and the flow rate of the steam pressure reducing valve cannot meet the application requirements. The other pressure reducing valve will automatically open.  

II. Large planned utilization flow

When planning to use steam with a large flow rate, it is recommended to select two or more sets of pressure reducing valves for parallel operation, which not only can stably control the outlet pressure, extend the service life, but also reduce costs; If the actual application flow is not as large as planned, the parallel connection of steam pressure reducing valves can sometimes become one for use and one for standby, which can ensure normal production.

(a: steam water separator b: bellows stop valve c: filter d: pressure reducing valve e: bellows stop valve f: bellows stop valve g: safety valve)

Reasonable steam decompression station, recommended:

In front of a pressure reducing valve station, it is necessary to install a steam water separator or a drain station with an equal diameter tee nearby to prevent condensate from damaging the water hammer of the pressure reducing valve.

It is necessary to install a 100 inch steam filter in front of the pressure reducing valve to prevent debris such as garbage from affecting the pressure reducing valve.

Fushan Valve (Suzhou) Co., Ltd. was first established in, and due to development needs, an independent legal entity was established: Fushan Valve (Jiangsu) Co., Ltd., with two holding factories in Suzhou and Kunshan. The company is committed to manufacturing high-quality Fushan brand valves in the fields of air conditioning water system, process cooling water (PCW system), compressed air (CDA system), pure water system, electric butterfly valve, electric ball valve, and steam pressure reducing valve, It has a large number of loyal customers including CSCEC, CEC, CEC, and the Institute of Physics of the Chinese Academy of Sciences.

CO
Contact: Zhang Li
Number: 13914960448/18068076259
销售电话:0512-57775199 57775177
外销邮箱:favalve@163.com
内销邮箱:sales@szfushan.com
Address:Block G, No. 499, Yujinxiang Road, Kunshan City, Suzhou City, Jiangsu Province
Copyright: Su ICP Bei 11005723-1
富山阀门(江苏)有限公司
富山阀门(苏州)有限公司

  Number

  13914960448

  18068076259

  Email

  sales@szfushan.com

     WeChat

    15250263448

    

Powered by Feedback Manage